YL18 G2 IP66 LED Waterproof Luminaire CCT switchable Power adjustable Through wiring Emergency Sensor Dali

Advantages
@ Reliable LED technology- maintenance
@ Diffuser with optical design ensures visual comfort
@ The light source module can be replaceable@ 3000, 4000 and 5000K color temperature in the same body and adjusted by selectorswitch@ Cable through foreasy and quick installation
@ Ceiling-mounted brackets and suspension hooks included
@ 150lm/w or 180lm/’w
@ Fast connector is optional for easy installation
◎ 5 years warranty



Specifications (150lm/W)
| Model | YL18 G2-18W-600 | YL18 G2-30W-1200 | YL18 G2-40W-1200 | YL18 G2-30W-1500 | YL18 G2-40W-1500 | YL18 G2-55W-1500 | YL18 G2-60W-1500 |
|---|---|---|---|---|---|---|---|
| Power | 18W | 30W | 40W | 30W | 40W | 55W | 60W |
| Input Voltage | AC220-240V | AC220-240V | AC220-240V | AC220-240V | AC220-240V | AC220-240V | AC220-240V |
| Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
| Efficiency | 2700lm | 4500lm | 6000lm | 4500lm | 6000lm | 8250lm | 9000lm |
| Body & Lens | PC | PC | PC | PC | PC | PC | PC |
| Body color | Grey (RAL7035) | Grey (RAL7035) | Grey (RAL7035) | Grey (RAL7035) | Grey (RAL7035) | Grey (RAL7035) | Grey (RAL7035) |
| LED driver | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud |
| LED type | SMD 2835 0.5W | SMD 2835 0.5W | SMD 2835 0.5W | SMD 2835 0.5W | SMD 2835 0.5W | SMD 2835 0.5W | SMD 2835 0.5W |
| Working temperature | -20°C to +40°C | -20°C to +40°C | -20°C to +40°C | -20°C to +40°C | -20°C to +40°C | -20°C to +40°C | -20°C to +40°C |
| IP Rate | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| IK Rate | IK08 | IK08 | IK08 | IK08 | IK08 | IK08 | IK08 |
| Beam Angel of light source | 120° | 120° | 120° | 120° | 120° | 120° | 120° |
| Protection class IEC | Saftey class I (I) | Saftey class I (I) | Saftey class I (I) | Saftey class I (I) | Saftey class I (I) | Saftey class I (I) | Saftey class I (I) |
| SDCM | <4 | <4 | <4 | <4 | <4 | <4 | <4 |
| Light source replaceable | YES | YES | YES | YES | YES | YES | YES |
| Init.Corr.Color Temperature | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K |
| Init.Color Rendering Index | 80 | 80 | 80 | 80 | 80 | 80 | 80 |
| Driver failure rate at 5000 h | <1 % | <1 % | <1 % | <1 % | <1 % | <1 % | <1 % |
| Power factor | >0.9 | >0.9 | >0.9 | >0.9 | >0.9 | >0.9 | >0.9 |
| Product Size (mm) | 640x79x68 | 1205x79x68 | 1205x79x68 | 1505x79x68 | 1505x79x68 | 1505x79x68 | 1505x79x68 |
| Innerbox Size (mm) | 680x85x72 | 1215x85x72 | 1215x85x72 | 1515x85x72 | 1515x85x72 | 1515x85x72 | 1515x85x72 |
| Carton Size (mm) | 695x305x275 | 1230x270x235 | 1230x270x235 | 1530x305x190 | 1530x305x190 | 1530x305x190 | 1530x305x190 |
| Qty / CTN | 12pcs | 9pcs | 9pcs | 8pcs | 8pcs | 8pcs | 8pcs |
Dimension

Specifications (180lm/W)
| Model | YL18 G2-25W-600 | YL18 G2-34W-1200 | YL18 G2-42W-1200 | YL18 G2-34W-1500 | YL18 G2-42W-1500 | YL18 G2-55W-1500 | YL18 G2-65W-1500 |
|---|---|---|---|---|---|---|---|
| Power | 25W | 34W | 42W | 34W | 42W | 55W | 65W |
| Input Voltage | AC220-240V | AC220-240V | AC220-240V | AC220-240V | AC220-240V | AC220-240V | AC220-240V |
| Frequency | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz |
| Efficiency | 4500lm | 6120lm | 7560lm | 6120lm | 7560lm | 9900lm | 11700lm |
| Body & Lens | PC | PC | PC | PC | PC | PC | PC |
| Body color | Grey (RAL7035) | Grey (RAL7035) | Grey (RAL7035) | Grey (RAL7035) | Grey (RAL7035) | Grey (RAL7035) | Grey (RAL7035) |
| LED driver | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud | PHILIPS / OSRAM / TRIDONIC / Boke / Lifud |
| LED type | SMD 2835 0.5W | SMD 2835 0.5W | SMD 2835 0.5W | SMD 2835 0.5W | SMD 2835 0.5W | SMD 2835 0.5W | SMD 2835 0.5W |
| Working temperature | -20°C to +40°C | -20°C to +40°C | -20°C to +40°C | -20°C to +40°C | -20°C to +40°C | -20°C to +40°C | -20°C to +40°C |
| IP Rate | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| IK Rate | IK08 | IK08 | IK08 | IK08 | IK08 | IK08 | IK08 |
| Beam Angel of light source | 120° | 120° | 120° | 120° | 120° | 120° | 120° |
| Protection class IEC | Saftey class I (I) | Saftey class I (I) | Saftey class I (I) | Saftey class I (I) | Saftey class I (I) | Saftey class I (I) | Saftey class I (I) |
| SDCM | <4 | <4 | <4 | <4 | <4 | <4 | <4 |
| Light source replaceable | YES | YES | YES | YES | YES | YES | YES |
| Init.Corr.Color Temperature | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K | 3000K 4000K 5000K 5700K 6500K |
| Init.Color Rendering Index | 80 | 80 | 80 | 80 | 80 | 80 | 80 |
| Driver failure rate at 5000 h | <1 % | <1 % | <1 % | <1 % | <1 % | <1 % | <1 % |
| Power factor | >0.9 | >0.9 | >0.9 | >0.9 | >0.9 | >0.9 | >0.9 |
| Product Size (mm) | 640x79x68 | 1205x79x68 | 1205x79x68 | 1505x79x68 | 1505x79x68 | 1505x79x68 | 1505x79x68 |
| Innerbox Size (mm) | 680x85x72 | 1215x85x72 | 1215x85x72 | 1515x85x72 | 1515x85x72 | 1515x85x72 | 1515x85x72 |
| Carton Size (mm) | 695x305x275 | 1230x270x235 | 1230x270x235 | 1530x305x190 | 1530x305x190 | 1530x305x190 | 1530x305x190 |
| Qty / CTN | 12pcs | 9pcs | 9pcs | 8pcs | 8pcs | 8pcs | 8pcs |
Dimension

Features

Product Photo


MANUAL INSTRUCTION

Why Choose IP66 LED Waterproof Luminaire for Harsh Environment Lighting
In factories, tunnels, subways and outdoor logistics yards, lighting fixtures are exposed to constant moisture, dust, vibration and aggressive cleaning. Under such conditions, many failures are not caused by LEDs themselves but by long-term electrical corrosion inside the luminaire. This is why an IP66 LED Waterproof Luminaire is no longer an optional upgrade, but a reliability baseline for industrial lighting projects.

In production plants, oil mist, metal dust and periodic high-pressure washing quickly expose the weaknesses of ordinary light fixtures. Non-sealed drivers slowly absorb moisture through cable entries and micro gaps, leading to electrolytic corrosion and unstable output.
IP66 luminaires eliminate this hidden aging mechanism completely. In complete factory lighting systems, they are often combined with
IP65 LED High Bay Lights
for high ceilings to create a layered ingress-protection strategy across different zones.
How IP66 Protection Fundamentally Changes Luminaire Failure Modes
Most luminaire failures in harsh environments begin with microscopic moisture penetration. Once humidity enters the driver chamber, corrosion of capacitors and solder joints becomes inevitable. The process is slow, invisible and often mistaken for random electronic defects.
Under the IEC 60529 ingress protection system, IP66 requires complete dust-tight sealing and resistance to powerful water jets from any direction :contentReference[oaicite:0]{index=0}. This level of sealing matches the real wash-down pressure found in food processing plants, car service zones and outdoor docks.

Subway tunnels introduce vibration and constant condensation on top of humidity. Non-sealed luminaires experience continuous internal breathing with each temperature cycle, slowly pumping moist air inside.
In these transit systems, IP66 luminaires are typically specified together with
IP65/IP66 LED Bulkhead
fixtures to maintain safe evacuation lighting under extreme moisture exposure.
What Buyers Truly Gain Beyond the “Waterproof” Label
The real value of IP66 LED Waterproof Luminaire selection goes far deeper than splash resistance. It directly determines electrical stability, capsule insulation life and the predictability of maintenance schedules.
Facilities depending on IP54 or IP65 fixtures frequently encounter rising failure probability after 12–18 months in humid zones. By contrast, IP66 fixtures typically sustain stable performance into fully planned relamping cycles.

Workshops combine high ambient heat, airborne metal particles and coolant mist — a hostile mix for electrical insulation. Conductive contamination quickly accumulates inside partially sealed luminaires.
IP66 luminaires prevent both vapor diffusion and particle migration, which is why they are frequently deployed with
IP65/IP66 LED Ceiling Lamps
in semi-outdoor production corridors.
Optical Stability and Visual Comfort Under Sealed Conditions
Modern IP66 luminaires no longer sacrifice optical performance for sealing. Precision diffusers and controlled beam distributions now deliver uniform illumination and glare control even at low mounting heights.

Reinforced polycarbonate bodies retain elasticity under thermal cycling, preserving gasket compression and long-term sealing integrity. This material behavior plays a direct role in whether the rated IP66 protection remains effective after years of operation.
Integration of Emergency, Sensor and DALI Control Inside IP66 Luminaires
Contemporary industrial lighting systems integrate emergency modules, microwave sensors and DALI dimming into sealed housings. Thermal separation between the LED driver and emergency battery pack becomes essential for long-term reliability.

Many ingress failures originate from incorrect on-site installation rather than factory defects. Proper gland torque, gasket alignment and cable routing are critical to preserving IP66 performance.
Detailed references such as the official
Yuanhui Installation Guide
significantly reduce human-factor ingress risks.
Why Engineering Standards Still Define True IP66 Reliability
Ingress protection alone does not equal full safety. IP66 LED Waterproof Luminaires must comply with luminaire safety standards under IEC 60598, while their sealing performance is validated under IEC 60529 :contentReference[oaicite:1]{index=1}.
For international projects, further conformity may involve
UL 1598
and CE Marking,
while photometric behavior is verified using LM-79 and LED lifetime using LM-80/TM-21 methods.
Position of IP66 LED Waterproof Luminaire in a Complete Lighting System
In a well-designed system, IP66 fixtures form the moisture-critical lighting layer, while adjacent dry zones may utilize
IP20 LED Batten Lights
for higher luminous efficiency where sealing is unnecessary.
Technical Basis and Source Validation
This analysis is based on ingress protection requirements defined by IEC 60529 and luminaire safety frameworks including IEC 60598 :contentReference[oaicite:2]{index=2}, together with standardized photometric testing under LM-79 and long-term lumen maintenance projections under LM-80/TM-21. Environmental behavior references real factory, workshop, subway and outdoor logistics lighting scenarios.
Why IP66 LED Waterproof Luminaire Becomes a Reliability Boundary
When moisture and particulate intrusion are permanently removed from the failure equation, long-term performance becomes a function of thermal design and standardized testing rather than environmental instability. That boundary is exactly what IP66 LED Waterproof Luminaires establish in harsh lighting applications.
Bulk Source YL18 G2 IP66 LED Waterproof Luminaire CCT switchable Power adjustable Through wiring Emergency Sensor Dali
Direct Factory Pricing | OEM/ODM Customization | GRS Certified Materials